HPC High Protection Cage Sicherheitsraum für IT / IT security room
SwissTe is a Swiss development company that provides security solutions in building services for IT environment. The focus of the HPC (High Protection Cage) is for housing and protection of information and telecommunication technologies.

Global sales is controlled exclusively through distributors (see Distributors page).

Further developments are in progress and will be introduced gradually through the coming months and years.

HPC
High Protection Cage


PDF booklet

The HPC market is another product made for the protection of information and telecommunications technology. With our partners we offer a holistic data center project that can be configured in any size and power class.
It was the choice of material for the HPC consciously paid to the use of inorganic, non-metallic materials. This enabled a space system can be created with highest mechanical requirements.
In addition, the space system is thereby flexibly adapt to the environment. Not the dimensions of components, but your requirements describe the size and structure of the HPC.
Special features of the HPCs:
  1. ECS-S Certified to EN1047-2 by ESSA
  2. Structural fire protection in F90, 120 or 180 (depending on demand) according to DIN 4102
  3. Water protection according to EN 50629 / IP 56
  4. Massive debris overload protection
Please contact us, we will contact you with your area representative.
The EN1047-2
What is the EN 1047-2 and what is behind it?
EN 1047-2: This standard was defined in the 1980s, within a professional and trade association (VDMA). In this standard, the limits are primarily IT, described in terms of temperature and humidity, as well as related test methods.
Why a separate standard for IT? Hardware and media subject in terms of temperature and humidity sensitive limits, as they are otherwise required for fire protection. (Defined in Germany by DIN 4102) in structural fire protection is the rescue of humans and animals in the foreground, in the protection of IT protection of property values. Therefore, in case of fire is the IT through a conventionally built fire apparatus (wall, door, bulkhead, etc.) are not adequately protected (see threshold table).

Temperature Limit & rel. HumidityTemperature rise / KelvinRel. HumidityDebris
EN 1047-2Max. 50K85%3.000 Nm impact test
DIN 4102 (F 30-180)max. 140-180Kundefinedundefined

Justification for the permissible temperature rises:
  • 70°C (20°C starting temp. plus rise of 50K): Destruction point for IT
  • 175°C: ignition temperature of paper

Deferrals EN 1047-2 compared to the structural fire protection
The following table limits and test conditions of EN 1047-2 and DIN 4102 are compared.

Requirements EN 1047-2 DIN 4102
Requirements / objectives Property values protection / protection of IT structures Personal and building protection
Test object System testing, including bulkheads, air-overpressure slide, door Component testing, connected to other components
Specimens closed with a base plate open
Limits max. 50K temperature rise 140K in the middle
180K maximum
Fire exposure 60 minutes 30/60/90/120/180 minutes
Measuring points Distance measuring 100mm Surface measurement
Post-heating over at least 12 hours not required
Humidity measurement called for 85% not required
Construction under the building regulations, with the legal requirements no given by general building approval / proof of applicability
Double-sided fire exposure not required demanded
Load-bearing walls, when tested with shock no demanded
Side mounting on shock test, with walls> 3 m allowed not allowed
Shock according to EN 1363/2 45th Minutes 1x 3,000 Nm 175th Minutes 3x 3,000 Nm (4102-3) complex wall / F180
Examination of integrity after the shock no demanded
Proof of stability as calculated static not required demanded
Watertightness not required not required
Exclusive distributor for Western Europe and Asia

PRIOR1 GmbH
Otto-von-Guericke-Str.8
53757 St.Augustin
Germany

www.prior1.com


Exclusive distributor for Easter Europe and Latin America

2 Group sp. z o. o.
ul. Jana Paw³a II 27
00-967 Warszawa
Poland

www.mdb.pl
European Security Systems Association eV, the European partner for safety with quality!

To provide the superior quality standards to prove it's for SwissTe absolutely logical that the High Protection Cage is tested according to the standards of the European Certification Body (ECB) and certified. Thus, we submit ourselves to the highest internationally recognized quality and standards for security products.

The European Security Systems Association ev, abbreviated ESSA is an international Verband the security industry. It supports the ECB•S certification of European Certification Body Inc.

According to its guiding principle "quality is safety" the ECB with its ECB•S certification mark highest security features according to European Standards. Currently around 1,000 valid ECB•S certificates are in the global security market. It gives users maximum security in investment decisions. For the insurance industry, it is a reliable and objective basis for the calculation of risks and the associated safety classification. 

In 1992 the ECB (former name: Research and Test safes and vaults eV, European Security Systems Association) has been accredited as a certification body to EN 45011. Responsible accreditation body is the present DAkkS German Accreditation Body FuP GmbH was founded in 1967 as a certification body for security products. ECB has thus more than 40 years experience in the testing and certification of security equipment.

Tests of EN 1047-2 are the ECB certified and monitored for quality. The quality control is carried out in relation to the EN 1047-2 / fire test, to supervision and monitoring manufacturers.

There are three accredited test institutes for EN 1047, and only one institution for EN 1047-2. Tests at other institutions do not meet the certification by the ESSA!


Druckfassung
SwissTe um ESSA
SwissTe GmbH

Gewerbestrasse 5
CH 6330 Cham

+49 151 41 36 08 82

info@swisste.ch
Privacy Policy

By using our website, you consent to the collection and use of information made available to us. All on the website of SwissTe personal data collected will be used exclusively for your individual care and processed. SwissTe assures you that your data in accordance with applicable data protection regulations will be treated confidentially.

Exclusions

This website has been compiled with great care. Nevertheless SwissTe not guarantee the correctness and accuracy of the information contained herein. SwissTe liable for any damages resulting directly or indirectly from the use of this website, unless they are based on intent or gross negligence of SwissTe.

Responsible for content

SwissTe GmbH
Gewerbestrasse 5
CH 6330 Cham

Manager

Dariusz Bujniewicz

Tel. +49 151 41 36 08 82

e-mail: info@SwissTe.com

UID: CHE-109.693.409
HrID: CH-270.4.013.233-1
MwSt-ID: CHE-109.693.409 MWST